Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Graefes Arch Clin Exp Ophthalmol ; 259(3): 759-768, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32945936

RESUMO

PURPOSE: To assess visual acuity in 5-year-old children with LEA chart and to estimate the frequency of reduced visual acuity in this age. METHOD: Study aimed at children attending the last year of preschool education in Public Kindergartens and Private Social Solidarity Institutions (IPSS) under the influence Regional Health Administration of the Médio Tejo, in Portugal. The 15-line LEA charts at 3 m were used and the presentation visual acuity was measured monocularly starting with the right eye. The ETDRS-fast methodology was used. RESULTS: A total of 3072 children participated, being 51% male and 54% from rural area. A rate of 13.7% children with a reduced level of visual acuity was found, that is, visual acuity worse or equal to 0.2 logMAR in at least one eye, or an interocular difference greater than two lines. CONCLUSION: This research shows that reduced VA frequency rate in children between 5 and 6 years old is high. The literature presents amblyopia (refractive and/or strabismic) and uncorrected refractive errors without amblyopia as the main cause of reduced VA in childhood, and these anomalies negatively affect child development, especially at the educational level. Reduced VA interferes with performance on a number of key tasks in the learning process. Thus, it is important to preserve the running program to identify these deficits and lead to their correction before the beginning of the school stage.


Assuntos
Ambliopia , Erros de Refração , Acuidade Visual , Ambliopia/fisiopatologia , Criança , Pré-Escolar , Feminino , Humanos , Masculino , Portugal , Testes Visuais
2.
J Dent Res ; 95(12): 1394-1400, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27470069

RESUMO

This study was designed to develop and characterize a silica-coating method for crystalline nonsilicate ceramic nanoparticles (Al2O3, TiO2, and ZrO2). The hypothesis was that the coated nonsilicate nanoparticles would stably reinforce a polymeric matrix due to effective silanation. Silica coating was applied via a sol-gel method, with tetraethyl orthosilicate as a silica precursor, followed by heat treatment. The chemical and microstructural characteristics of the nanopowders were evaluated before and after silica coating through x-ray diffraction, BET (Brunauer-Emmett-Teller), energy-dispersive x-ray spectroscopy, field emission scanning electron microscopy, and transmission electron microscopy analyses. Coated and noncoated nanoparticles were silanated before preparation of hybrid composites, which contained glass microparticles in addition to the nanoparticles. The composites were mechanically tested in 4-point bending mode after aging (10,000 thermal cycles). Results of all chemical and microstructural analyses confirmed the successful obtaining of silica-coated nanoparticles. Two distinct aspects were observed depending on the type of nanoparticle tested: 1) formation of a silica shell on the surface of the particles and 2) nanoparticle clusters embedded into a silica matrix. The aged hybrid composites formulated with the coated nanoparticles showed improved flexural strength (10% to 30% higher) and work of fracture (35% to 40% higher) as compared with composites formulated with noncoated nanoparticles. The tested hypothesis was confirmed: silanated silica-coated nonsilicate nanoparticles yielded stable reinforcement of dimethacrylate polymeric matrix due to effective silanation. The silica-coating method presented here is a versatile and promising novel strategy for the use of crystalline nonsilicate ceramics as a reinforcing phase of polymeric composite biomaterials.


Assuntos
Resinas Compostas/química , Materiais Dentários/química , Nanopartículas/química , Dióxido de Silício/química , Óxido de Alumínio/química , Desenho Assistido por Computador , Análise do Estresse Dentário , Teste de Materiais , Microscopia Eletrônica de Varredura , Microscopia Eletrônica de Transmissão , Polímeros/química , Silanos/química , Espectrometria por Raios X , Propriedades de Superfície , Resistência à Tração , Titânio/química , Difração de Raios X , Zircônio/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...